Philips Zenition 90

Advanced C-arm for complex procedures

Key features

  • 15 kW high-frequency generator
  • 21 × 21 cm or 30 × 30 cm flat detector
  • Touch Screen Module for imaging control directly from the sterile field
  • Fully counterbalanced C-arm for smooth manual positioning
  • Position Memory for returning to up to 3 stored positions
  • Automatic Vascular Outlining
  • Injector Interface
  • Personalized IQ with application-specific protocols and customizable presets
  • DoseWise
  • MetalSmart
  • BodySmart
  • Active oil circulation and optimized heat management
  • Unify Workflow, ClearGuide and Color Coding
  • Wi-Fi connectivity
  • Philips Remote Services

Primary clinical applications

  • Orthopedics
  • Trauma
  • Pain management
  • Spine
  • Urology
  • Abdominal
  • Vascular

Additional clinical applications

  • Cardiac

Direct imaging control from the sterile field

Essential imaging functions available directly at the patient table

The Touch Screen Module enables users to control imaging functions directly from the sterile area. Its tablet-like interface allows imaging parameters to be adjusted, images to be collimated and rotated, and acquired images to be reviewed without moving to the main workstation.

The module displays the same clinical image as the Mobile View Station and provides functionality comparable to the C-arm mounted screen, giving users more direct control over imaging during procedures.

Philips Zenition 90 - Dacorum Grup
Philips Zenition 90 - Dacorum Grup

Power and endurance for complex procedures

Sustained performance for steep angulations and dense anatomies

The 15 kW generator provides the power required for complex and extended procedures, including situations involving steep angles or imaging of dense anatomies.

Active oil circulation and optimized heat management support longer fluoroscopy times and help maintain system performance during extended procedures.

Flat detector for flexibility and anatomical coverage

Two detector sizes adapted to different clinical requirements

Zenition 90 can be configured with a 21 × 21 cm flat detector for increased positioning flexibility or a 30 × 30 cm detector for broader anatomical coverage.

Flat Detector technology delivers distortion-free imaging and is combined with Philips image processing and dose management technologies to support visualization of complex structures and dense anatomy.

Advanced vascular workflow

Contrast control and rapid visualization of vascular structures

Through the Injector Interface, users can start and adjust contrast injections in relation to X-ray acquisition, including directly from the patient table through the Touch Screen Module.

The Automatic Vascular Outlining function enables rapid outlining of vascular edges on subtraction images. It helps simplify the imaging workflow and supports faster identification of vascular structures of interest.

Reproducible positioning and intuitive workflow

Accurate return to previously used projections

The Position Memory function allows up to three C-arm positions to be stored while displaying the coordinates of the current and saved positions. Users can therefore guide the system back to the required projection more quickly and reproducibly.

ClearGuide and Color Coding, integrated within Unify Workflow, support positioning coordination and communication between team members during procedures.

Customizable protocols and parameters

Configuration adapted to the procedure, patient and user

The Personalized IQ function provides application-specific protocols and customizable presets for different types of procedures and patients. These help standardize imaging parameters and simplify system preparation.

Users can create individual profiles containing their preferred imaging parameters and general settings. When a profile is selected, the system automatically loads the associated configuration, reducing the need for repeated adjustments during procedures.