Philips Zenition 90 Motorized
Motorized C-arm for complex procedures
Key features
4-axis motorization, with speeds of up to 15°/second
Direct table-side control through the Table Side Operator
Touch Screen Module for imaging function control
Automatic Position Control for returning automatically to one of 3 stored positions
BodyGuard collision prevention system
15 kW or 25 kW generator
21 × 21 cm or 30 × 30 cm digital detector
Automatic Vascular Outlining
Injector Interface
Personalized IQ with application-specific protocols and customizable presets
DoseWise, MetalSmart and BodySmart
Electromagnetic brakes
Motorized and manual operating modes
Wi-Fi connectivity and Philips Remote Services
Primary clinical applications
- Orthopedics
- Trauma
- Pain management
- Spine
- Urology
- Abdominal
- Vascular
- Cardiac
Direct table-side control and greater independence
Motorized positioning control without leaving the sterile area
The 4-axis motorization enables fast and precise control of C-arm movements directly from the patient table using the Table Side Operator. Angulation and rotation can be controlled with a single joystick, with variable speeds of up to 15°/second, supporting efficient repositioning during procedures.
The Automatic Position Control function allows the system to return quickly and accurately to one of three stored positions. Previously used projections can be reproduced with less effort, helping streamline procedures that require repeated repositioning.


Imaging for complex and extended procedures
High power and extended anatomical coverage
Zenition 90 Motorized is available with a 15 kW or 25 kW generator, supporting procedures that require steep angulations, lateral projections and extended periods of fluoroscopy.
The system can be configured with a 21 × 21 cm digital detector for increased positioning flexibility or a 30 × 30 cm detector for broader anatomical coverage. Active oil circulation and improved heat management support longer procedures and intensive use.
Advanced vascular workflow
Contrast control and automatic visualization of vascular structures
Through the Injector Interface, users can adjust and start contrast injections in relation to X-ray acquisition, directly from the patient table or from other areas of the operating room.
The Automatic Vascular Outlining function enables rapid outlining of vascular edges on subtraction images. It helps simplify the imaging workflow during vascular procedures and supports faster visualization of the structures of interest.
Customizable protocols and parameters
Configuration adapted to the procedure and the user
The Personalized IQ function provides application-specific protocols and customizable presets for different types of procedures and patients. Image quality and dose parameters can be configured quickly, helping standardize system setup.
Users can create individual profiles in which imaging preferences and general settings are stored. When a user logs in, the system automatically loads the associated configuration, reducing the need for repeated adjustments before and during procedures.
Safety and motion control
Fast positioning with protection against accidental contact
The BodyGuard system uses sensors integrated into the detector to identify the patient’s proximity and help prevent accidental contact while the C-arm is moving.
Electromagnetic brakes allow movements to be locked and unlocked quickly, while the system can be switched between motorized and manual operation. This gives the medical team additional flexibility to adapt positioning to the requirements of each procedure.